Gas Chromatography System LTCGR8-8

Used in Food Testing, Chemical Industry, Beverage Testing, Drug testing, Forensic Science, Pharmaceutical, Molecular Biology, Medical, Research, Laboratory

  • The host uses a 7-inch color touch screen, electronic display gas flow and pressure values.
  • Computer anti-control (need to choose PC-side anti-control software) and the host touch screen to achieve synchronous two-way control.
  • Multi-core, 32-bit embedded hardware system to ensure reliable operation of the instrument.
  • One key to start function.
Price: $7,480.00
Download Catalog
Get Quote

Features

  • The host uses a 7-inch color touch screen, electronic display gas flow and pressure values.
  • Computer anti-control (need to choose PC-side anti-control software) and the host touch screen to achieve synchronous two-way control.
  • Multi-core, 32-bit embedded hardware system to ensure reliable operation of the instrument.
  • One key to start function.
  • Extensible synchronous external triggering function can be initiated by external signals (autosampler, thermal analyzer, etc.) at the same time to start the host and workstation.
  • It has a perfect system self-test function and automatic fault recognition.
  • Extended interface with 8 external events, which can be equipped with various function control valves and operate according to their own timing.
  • 20 sets of sample test mode memory function.

Specifications

Column Oven: 
      Inner volume22 L
      Temperature Range5°C – 400°C (room temperature)
      Temperature Control Accuracy± 0.1°C
      Heating Rate0.1 - 60°C /min
      The order of heating of the program9
      Program Temperature Repeatability≤ 2%
      Cooling MethodAfter the door
      Cooling Rate≤ 10 mins (250°C – 50°C)
Sampler: 
      Temperature Control Range7°C – 420°C (room temperature)
      Temperature Control ModeIndependent temperature control
      Carrier gas flow control modeConstant pressure
      Number of simultaneous installationsUp to 3
      Injection unit typePacked column, shunt
      Split ratioDisplay
      Pre column pressure range0-400 kpa
      Pre column pressure control accuracy0.1 kpa
      Flow setting rangeH20 - 200 ml / min N20 – 150 ml / min
Hydrogen flame ionization detector (FID): 
      Temperature control range7°C – 420°C (room temperature)
      Number of simultaneous installationsUp to 2
      Ignition functionAutomatic
      Detection limit≤ 3x10-12 g/s (n-hexadecane)
      Baseline noise≤ 5x10-14 A
      Baseline drift≤ 6x10-13 A
      Dynamic range107
      RSD≤ 3%
Thermal Conductivity Detector (TCD): 
      Sensitivity5000 mV.ml / mg (n-hexadecane)
      Baseline noise≤0.05 mV
      Baseline drift≤0.15 mV / 30 min
      Dynamic range105
Other Specifications: 
      Power supply voltage220 V ± 22 V, 50 Hz ± 0.5 Hz
      Power3000 W