Gas Chromatography System LTCGR8-8
Used in Food Testing, Chemical Industry, Beverage Testing, Drug testing, Forensic Science, Pharmaceutical, Molecular Biology, Medical, Research, Laboratory
- The host uses a 7-inch color touch screen, electronic display gas flow and pressure values.
- Computer anti-control (need to choose PC-side anti-control software) and the host touch screen to achieve synchronous two-way control.
- Multi-core, 32-bit embedded hardware system to ensure reliable operation of the instrument.
- One key to start function.
Price: $7,480.00
Download Catalog
Get Quote
Download Catalog
Get Quote
Features
- The host uses a 7-inch color touch screen, electronic display gas flow and pressure values.
- Computer anti-control (need to choose PC-side anti-control software) and the host touch screen to achieve synchronous two-way control.
- Multi-core, 32-bit embedded hardware system to ensure reliable operation of the instrument.
- One key to start function.
- Extensible synchronous external triggering function can be initiated by external signals (autosampler, thermal analyzer, etc.) at the same time to start the host and workstation.
- It has a perfect system self-test function and automatic fault recognition.
- Extended interface with 8 external events, which can be equipped with various function control valves and operate according to their own timing.
- 20 sets of sample test mode memory function.
Specifications
| Column Oven: | |
| Inner volume | 22 L |
| Temperature Range | 5°C – 400°C (room temperature) |
| Temperature Control Accuracy | ± 0.1°C |
| Heating Rate | 0.1 - 60°C /min |
| The order of heating of the program | 9 |
| Program Temperature Repeatability | ≤ 2% |
| Cooling Method | After the door |
| Cooling Rate | ≤ 10 mins (250°C – 50°C) |
| Sampler: | |
| Temperature Control Range | 7°C – 420°C (room temperature) |
| Temperature Control Mode | Independent temperature control |
| Carrier gas flow control mode | Constant pressure |
| Number of simultaneous installations | Up to 3 |
| Injection unit type | Packed column, shunt |
| Split ratio | Display |
| Pre column pressure range | 0-400 kpa |
| Pre column pressure control accuracy | 0.1 kpa |
| Flow setting range | H20 - 200 ml / min N20 – 150 ml / min |
| Hydrogen flame ionization detector (FID): | |
| Temperature control range | 7°C – 420°C (room temperature) |
| Number of simultaneous installations | Up to 2 |
| Ignition function | Automatic |
| Detection limit | ≤ 3x10-12 g/s (n-hexadecane) |
| Baseline noise | ≤ 5x10-14 A |
| Baseline drift | ≤ 6x10-13 A |
| Dynamic range | 107 |
| RSD | ≤ 3% |
| Thermal Conductivity Detector (TCD): | |
| Sensitivity | 5000 mV.ml / mg (n-hexadecane) |
| Baseline noise | ≤0.05 mV |
| Baseline drift | ≤0.15 mV / 30 min |
| Dynamic range | 105 |
| Other Specifications: | |
| Power supply voltage | 220 V ± 22 V, 50 Hz ± 0.5 Hz |
| Power | 3000 W |