Gas Chromatography System LTCGR8-9

Used in Food Testing, Chemical Industry, Beverage Testing, Drug testing, Forensic Science, Pharmaceutical, Molecular Biology, Medical, Research, Laboratory

  • Control system is designed for monitoring and controlling the instrument via the computer.
  • Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature.
  • Advanced built-in data acquisition system, supporting real time instrument status monitoring, detection signal acquisition and PC control.
  • Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening.
Price: $6,365.00
Download Catalog
Get Quote

Features

  • Control system is designed for monitoring and controlling the instrument via the computer.
  • Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature.
  • Advanced built-in data acquisition system, supporting real time instrument status monitoring, detection signal acquisition and PC control.
  • Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening.
  • Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.
  • High sensibility and stability detector.
  • 2 independent and analog signals output.
  • M6 software, compatible with GLP/FDA-21 CFR Part 11 requirements and regulations (electronic records and signatures).
  • Sample injector and evaporation chamber.

Specifications

Column Oven: 
      Temperature RangeAmbient temperature +7°C ~ 400°C (in 1°C increment)
      Temperature Control Accuracy± 0.02°C
      Programmed temperature setting0.1°C ~ 40°C/min (in 1°C increment)
      Program ramps7 ramps in total (10 ramps available with control workstation)
      Cooling time400°C to 50°C in 8-10 min at 25°C ambient
      Size (LxWxH)284x280x241mm (internal) 340x345x281mm (external)
Hydrogen flame ionization detector (FID): 
      Detection limit≤ 3x10-12 g/s (C16)
      Best test result≤ 3x10-12 g/s (C16)
      Baseline noise≤ 5x10-14 A
      Baseline drift≤ 6x10-13 A /30 min
      Linear range≥ 106
Thermal Conductivity Detector (TCD): 
      Sensitivity≥5000 mV.ml / mg (C 16)
      Baseline noise≤20 μV
      Baseline drift≤60 μV/h
      Linearity range≥104
Flame Photometric Detector (FPD): 
      Detection limit≤8x10 g / s (P)
≤8x10 g / s (S)Flame Photometric Detector (FPD): Drift
≤2x10-11 A/30 minFlame Photometric Detector (FPD): Baseline noise