
Gas Chromatography System LTCGR8-9
Used in Food Testing, Chemical Industry, Beverage Testing, Drug testing, Forensic Science, Pharmaceutical, Molecular Biology, Medical, Research, Laboratory
- Control system is designed for monitoring and controlling the instrument via the computer.
- Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature.
- Advanced built-in data acquisition system, supporting real time instrument status monitoring, detection signal acquisition and PC control.
- Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening.
Price: $6,365.00
Download Catalog
Get Quote
Download Catalog
Get Quote
Features
- Control system is designed for monitoring and controlling the instrument via the computer.
- Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature.
- Advanced built-in data acquisition system, supporting real time instrument status monitoring, detection signal acquisition and PC control.
- Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening.
- Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.
- High sensibility and stability detector.
- 2 independent and analog signals output.
- M6 software, compatible with GLP/FDA-21 CFR Part 11 requirements and regulations (electronic records and signatures).
- Sample injector and evaporation chamber.
Specifications
| Column Oven: | |
| Temperature Range | Ambient temperature +7°C ~ 400°C (in 1°C increment) |
| Temperature Control Accuracy | ± 0.02°C |
| Programmed temperature setting | 0.1°C ~ 40°C/min (in 1°C increment) |
| Program ramps | 7 ramps in total (10 ramps available with control workstation) |
| Cooling time | 400°C to 50°C in 8-10 min at 25°C ambient |
| Size (LxWxH) | 284x280x241mm (internal) 340x345x281mm (external) |
| Hydrogen flame ionization detector (FID): | |
| Detection limit | ≤ 3x10-12 g/s (C16) |
| Best test result | ≤ 3x10-12 g/s (C16) |
| Baseline noise | ≤ 5x10-14 A |
| Baseline drift | ≤ 6x10-13 A /30 min |
| Linear range | ≥ 106 |
| Thermal Conductivity Detector (TCD): | |
| Sensitivity | ≥5000 mV.ml / mg (C 16) |
| Baseline noise | ≤20 μV |
| Baseline drift | ≤60 μV/h |
| Linearity range | ≥104 |
| Flame Photometric Detector (FPD): | |
| Detection limit | ≤8x10 g / s (P) |
| ≤8x10 g / s (S) | Flame Photometric Detector (FPD): Drift |
| ≤2x10-11 A/30 min | Flame Photometric Detector (FPD): Baseline noise |
