Ion Chromatography System LTCGR8-2
Used in Food Testing, Chemical Industry, Beverage Testing, Drug testing, Forensic Science, Pharmaceutical, Molecular Biology, Medical, Research, Laboratory
- Temperature-control bipolar conductivity detector:
- Greater detection range, better precise analysis.
- Built-in circulating 3D constant temperature technology:
- Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data.
Price: $29,949.00
Download Catalog
Get Quote
Download Catalog
Get Quote
Features
- Temperature-control bipolar conductivity detector:
- Greater detection range, better precise analysis.
- Built-in circulating 3D constant temperature technology:
- Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data.
- The world's leading full-range series of ion chromatographic columns:
- High efficiency, large capacity of the columns for detecting ions of varied
- compositions.
- Self-Regenerating Electrolytic Micro-membrane Suppressor:
- High pressure resistance, small dead volume, highly responsive to signals.
- Able to detect anions and cations at the ppb level.
- Work across a variety of detectors, to expand the scope of applications of ion chromatography.
Specifications
Ion Chromatographic Pump: | |
Maximum Pressure | 35 Mpa (PEEK) |
Type | High-pressure and low-pulse two-piston tandem advection pump |
Pressure Display Accuracy | ≤ 0.1 MPa |
Flow Range | 0.001 ~ 9.999 mL/min |
Pressure Pulse | ≤ 0.5% |
Flow Stability | (0.2-0.5) mL/min ≤ 3%; (0.5-1.0) mL/min ≤ 2%; > 1.0 mL/min ≤ 2% |
Allowable Deviation of Flow | (0.2-0.5) mL/min ±5%; (0.5-1.0) mL/min ±3%; > 1.0 mL/min ±2% |
Numerical-control and Electromagnetic Sample Injector: | |
Maximum Pressure | 35 Mpa |
Contact Material of the Rotor | PEEK |
Control Mode | By Stepper motor |
Power Supply | 24 V (DC) |
Conduction Detection System: | |
Type | Temperature control and bipolar conductivity detector |
Cell Volume | ≤0.8μL |
Detection Mode | Bipolar conductivity detection |
Detection Range | 0~45000 μS/cm |
Detection Resolution | ≤0.0020nS/cm |
Output Voltage | -6000~+6000 mv (adjustable) |
Electronic Noise | 0.02 nS |
Baseline Noise | ≤ 0.001 μS/cm |
Baseline Drift | ≤ 0.02μS |
Operating Temperature Range | Room temperature +5°C~60°C |
Controlling Temperature Accuracy | ±0.01°C |
Maximum Pressure | 10.0 Mpa |
Linear Range | ≥ 10 3 |
Instrument Linearity | ≥0.999 |
Quantitative Repeatability | ≤1.0% |
Qualitative Repeatability | ≤0.1% |
Minimum Detectable Concentration | Cl- ≤ 0.0005 ug/mL; Li+ ≤ 0.001 ug/mL; BrO3≤ 0.001 ug/mL |
Flow System: | |
Six-way Valve | PEEK material, pressure 5000 psi; Independent automatic collecting and flow function. |
Suppressor: | |
Type | Self-Regenerating electrolytic micro-membrane suppressor |
Maximum Pressure | 6.0 Mpa |
Dead Volume | <50 μL |
Other Specifications: | |
Dimension (LxWxH) | 350x470x510 mm |
Net Weight | 26 kg |
Gross Weight | 32 kg |
Power | 150 W |