Home /
Chromatography Systems
/ Ion Chromatography Systems
/ Portable Ion Chromatography System LTCGR8-6
Portable Ion Chromatography System LTCGR8-6
Used in Food Testing, Chemical Industry, Beverage Testing, Drug testing, Forensic Science, Pharmaceutical, Molecular Biology, Medical, Research, Laboratory
- Powerful data processing system:
- Iconic display, customizable interface, integration of instrument control, data analysis and processing, data sharing module for on-site and remote data sharing through 4G network.
- Quick chromatographic columns for 5-min rapid detection:
- Original quick chromatographic columns for on-site quick detection of anions and cations.
Price: $67,469.00
Download Catalog
Get Quote
Download Catalog
Get Quote
Features
- Powerful data processing system:
- Iconic display, customizable interface, integration of instrument control, data analysis and processing, data sharing module for on-site and remote data sharing through 4G network.
- Quick chromatographic columns for 5-min rapid detection:
- Original quick chromatographic columns for on-site quick detection of anions and cations.
- Intelligent flow path cleaning makes easier cleaning:
- The flow path is designed with a switching valve for free switch of eluent bottles and pure water bottles.
- WI-FI communication, real-time operation:
- Being equipped with a tablet/laptop makes real-time operation more flexibly and conveniently.
- Upgrade-supported dual detectors (Conductivity Detector and ampere detector) to meet the needs of different industries.
Specifications
Ion Chromatographic Pump: | |
Maximum Pressure | 35 Mpa (PEEK) |
Type | High-pressure and low-pulse two-piston tandem advection pump |
Flow Range | 0.001 ~ 9.999 mL/min |
Flow Accuracy | ±0.5% |
Flow Repeatability | RSD≤0.1% |
Flow Stability | (0.2-0.5) mL/min ≤ 3%; (0.5-1.0) mL/min ≤ 2%; > 1.0 mL/min ≤ 2% |
Numerical-control and Electromagnetic Sample Injector: | |
Maximum Pressure | 35 Mpa |
Control Mode | By Stepper motor |
Power Supply | 24 V (DC) |
Column Heater: | |
Operating Temperature Range | Room temperature +5°C~60°C(41~140°F) |
Allowable Deviation of Column Heater’s Temperature | ± 1°C |
Temperature Stability | ≤ 0.5°C/h |
Conduction Detection System: | |
Type | Temperature control and bipolar conductivity detector |
Cell Volume | ≤0.8μL |
Detection Mode | Bipolar conductivity detection |
Detection Range | 0~45000 μS/cm (adjustable) |
Detection Resolution | ≤0.0020nS/cm |
Output Voltage | -6000~+6000 mv (adjustable) |
Baseline Noise | ≤0.5% FS |
Baseline Drift | ≤ 20% FS/30 min |
Operating Temperature Range | Room temperature +5°C~60°C(41~140°F) |
Controlling Temperature Accuracy | ±0.01°C |
Maximum Pressure | 10.0 Mpa |
Instrument Linearity | ≥0.999 |
Quantitative Repeatability | ≤0.5% |
Qualitative Repeatability | ≤2% |
Minimum Detectable Concentration | Cl- ≤ 0.005 ug/mL; Li+ ≤ 0.001 ug/mL |
Flow System: | |
Six-way Valve | PEEK material, pressure 5000 psi; Independent automatic collecting and flow function. |
Panel Computer: | |
Display Screen | 12.3 inch |
Internal Memory | 2 G |
Weight | 786 g |
Maximum Pressure | 20 Mpa |
Minimum Pressure | 5 Mpa |
Suppressor: | |
Maximum Pressure | 6.0 Mpa |
Dead Volume | <30 μL |
Other Specifications: | |
Dimension (LxWxH) | 330x220x310 mm |
Net Weight | 8 kg |
Gross Weight | 11 kg |
Battery Capacity | 5000 mAh |
Power | 150 W |