Semi Automatic Cryostat LTHIS8-3
Used in Tissue biopsy, Slice tissue slide, Magnetic Resonance Imaging (MRI), Pathological diagnosis, Analysis and Research in Hospital and Medical colleges.
Also known as Ultrafine "deli-slicer"
- Adjustable cool plate temperature with -45℃ minimum. Super large, may hold 28 chucks at meantime. New designed hammer make the tissues platter than the traditional one. Adjustable temperature with -50 ℃ minimum. Cutting angle is12°universally adjustable to meet varieties of needs. Retraction function to avoid scratches on specimen. Freezing chamber adjustable temperature with - 40 ℃ minimum. The handwheel can be locked at any position. Injection moulding shell with mild feeling is durable and easy to clean. 40 decibel silent freezing system with duel compressors made in Germany. Blade holder auto pump-blade device may avoid incised wound. Anti-fog glass window.
Price: $12,261.00
Download Catalog
Get Quote
Download Catalog
Get Quote
Features
- Adjustable cool plate temperature with -45℃ minimum. Super large, may hold 28 chucks at meantime. New designed hammer make the tissues platter than the traditional one. Adjustable temperature with -50 ℃ minimum. Cutting angle is12°universally adjustable to meet varieties of needs. Retraction function to avoid scratches on specimen. Freezing chamber adjustable temperature with - 40 ℃ minimum. The handwheel can be locked at any position. Injection moulding shell with mild feeling is durable and easy to clean. 40 decibel silent freezing system with duel compressors made in Germany. Blade holder auto pump-blade device may avoid incised wound. Anti-fog glass window.
Specifications
Freezing chamber temperature range | - 40 ℃ ~ -10 ℃ |
Freezing shelf minimum temperature | - 45 ℃ |
Chuck holder minimum temperature | - 50 ℃ |
Minimum temperature of Peltier element on freezing shelf | - 60 ℃ |
Number of Peltier element cooling spot | 2 |
Maximum specimen size | 50×80 mm |
Chuck hold maximum adjustable angle | 12 ° |
Specimen vertical stroke | 70 mm |
Specimen horizontal stroke | 20 mm |
Rough feeding speed | (0.9 mm/s; 0.3 mm/s) |
Section thickness range 1 μm~100 μm adjustable | 1 μm ~ 20 μm, in 1 μm increments |
Section thickness range 1 μm ~ 100 μm adjustable | 50 μm~100 μm, in 5 μm increments. |
Trimming thickness range 10 μm ~ 400 μm adjustable | 50 μm ~ 100 μm, in 10 μm increments |
Trimming thickness range 10 μm ~ 400 μm adjustable | 100 μm ~ 400 μm, in 50 μm increments |
Retraction range 0μm~80μm adjustable, in 5μm increment | 0 μm ~ 80 μm adjustable, in 5 μm increment |
Voltage and frequency | AC 220 V ± 10 %, 50 Hz (Standard) or AC 110 V ± 10 %, 60 Hz |
Power | 800 W |
Net weight | 125 kg |
Dimensions(W×D×H) | 660×640×1130 mm |