Thermogravimetric analysis LTTAN19-1
Thermogravimetric analysis is a technique that measures the mass changes in the sample as a function of temperature under the controlled atmosphere. The equipment consists of a furnace to control the heat while a balance to measure the changes in the weight of the sample. TGA has a broad range of applications which includes determining the composition of complex molecules (polymers, composites, etc.), evaluating thermal stability, and measuring the moisture & volatile content of the sample.
Also known as Thermal gravimetric analysis, TGA
- Industrial level widescreen touch structure is rich in information, including setting temperature, sample temperature,
- oxygen flow, nitrogen flow, differential thermal signal, various switch states, etc
- Use the gigabit network line communication interface, the universality is strong, the communication is reliable
- without interruption, supports the self-recovery connection function.
Price: $15,768.00
Download Catalog
Get Quote
Download Catalog
Get Quote
Features
- Industrial level widescreen touch structure is rich in information, including setting temperature, sample temperature,
- oxygen flow, nitrogen flow, differential thermal signal, various switch states, etc
- Use the gigabit network line communication interface, the universality is strong, the communication is reliable
- without interruption, supports the self-recovery connection function.
- The furnace body is compact, temperature rise and fall speed adjustable
- Water bath and heat insulation system, insulation high temperature furnace body temperature on the weight of the balance.
- Improved installation process, all adopt mechanical fixation; The sample support rod can be replaced flexibly and crucible can be matched with various models according to the requirements, so that users can have different Requirements
Specifications
Temperature Range | RT-1250°C |
Temperature resolution | 0.01°C |
Cooling rate | 0.1°C/min-30°C/min (When more than 100°C, Cooling rate Constant temperature can lower the temperature RT-1250°C at a cooling rate) |
Temperature Fluctuation | ±0.1°C |
Heating Rate | 0.1-80°C |
Constant Temperature | RT-1250°C |
Duration of constant temperature | 0-300min (When more than 1000°C, the duration recommended to be less than 30 mins |
Balance measurement range | 2g (optional range 10g, 50g, etc.) |
Temperature Control mode | PID temperature control |
Gas control | Nitrogen, Oxygen (automatic switching) |
Weight resolution | 10.0.01mg (optional other resolution 1ug, 0.1ug, 0.01ug,etc.) |
Machine Size | 0 cm*44cm*42 cm, 50kg (65kg, with the outer packing) |
Standard Crucible size | 10 mmx 6mm |
Communication method | 13.Gigabit gateway Communication methods |
Power | 12.1000W, AC220V 50Hz or customize other standard power sources |